Farm applications & use guidance

Hyperox’ unique formulation, broad spectrum of activity and enhanced stability make it the peracetic acid disinfectant of choice for farm; general surface, equipment, water delivery system and thermal fogging disinfection.

Application & Use Guidance

Surface DisinfectionDilution RateApplication
Routine disinfection for all pre-cleaned surfaces including wood and concrete1:100 (10ml of Hyperox™ concentrate to 1 litre of water)Using mechanical spraying equipment, apply Hyperox™ solution at an application rate of 300ml/m2.

Example: Routine disinfection of a 1000m2 house, with a total surface area of 2500m2 including walls and ceiling, at a dilution rate of 1:100 and an application rate of 300 mls/m2 or to point of run-off, will require a solution consisting of 7.5 litres of Hyperox™ concentrate added to 750 litres of water. This calculation is based on typical UK conversion rates: please check your country/regional specific requirements. 

Equipment DisinfectionDilution RateApplication
Routine disinfection of clean movable equipment1:100 (10ml of Hyperox™ concentrate to 1 litre of water)Spray all equipment with Hyperox™ solution to point of run-off.


Disinfectant Foot & Wheel DipsDilution RateApplication
Routine disinfection of clean movable equipment1:100 (10ml of Hyperox™ concentrate to 1 litre of water)Replace solution once it has either become soiled or after a period of 2 days.

 

Water Systems

All water systems contain some microbial contamination, especially header tanks where dust and debris can accumulate. Disinfecting will clean the system and eliminate waterborne pathogens, including bacteria and viruses.

Water System DisinfectionDilution RateApplication
Terminal disinfection of water systems1:100 (10ml of Hyperox™ concentrate to 1 litre of water)Isolate header tank at the mains and drain system. Clean out any gross soiling and debris. Refill with clean water and add the appropriate volume of Hyperox™ concentrate, stir thoroughly and leave for 1 hour. This will help remove biofilm from the inner surface of the drinking water system. Flush system through and refill with clean water.